From: Bauer, Robert <Robert.Bauer>
Date: Thu, 8 Oct 2020 19:13:06 +0000

Dear Tingjie:
When used in nonmem 7.5, a recommended example/setup would be (as shown on =
page 152 of nm750.pdf)

$SIZES ISAMPLEMAX=250
...
$EST METHOD=SAEM NBURN=500 NITER=1000 MASSRESET=1 ISAMPLE=2
     PRINT=20 NOPRIOR=1 RANMETHOD=P
$EST METHOD=SAEM NBURN=0 NITER=0 MASSRESET=0 ETASAMPLES=1 ISAMPLE=
=200 EONLY=1
$EST METHOD=IMP NITER=5 MASSRESET=1 ETASAMPLES=0 ISAMPLE=1000
     EONLY=1 PRINT=1 MAPITER=0

Robert J. Bauer, Ph.D.
Senior Director
Pharmacometrics R&D
ICON Early Phase
820 W. Diamond Avenue
Suite 100
Gaithersburg, MD 20878
Office: (215) 616-6428
Mobile: (925) 286-0769
Robert.Bauer
www.iconplc.com<http://www.iconplc.com> <br /><br /> ICON plc made the =
following annotations. --------------------------------------------------=
---------------------------- This e-mail transmission may contain confide=
ntial or legally privileged information that is intended only for the indiv=
idual or entity named in the e-mail address. If you are not the intended =
recipient, you are hereby notified that any disclosure, copying, distributi=
on, or reliance upon the contents of this e-mail is strictly prohibited. If=

 sender, so that ICON plc can arrange for proper delivery, and then please =
delete the message. Thank You, ICON plc South County Business P=
ark Leopardstown Dublin 18 Ireland Registered number: 145835


Received on Thu Oct 08 2020 - 15:13:06 EDT

The NONMEM Users Network is maintained by ICON plc. Requests to subscribe to the network should be sent to: nmusers-request@iconplc.com.

Once subscribed, you may contribute to the discussion by emailing: nmusers@globomaxnm.com.