NONMEM Users Network Archive

Hosted by Cognigen

[NMusers] Unable to achieve Cmax

From: Anuja Dhas <Anuja.Dhas_at_Cipla.com>
Date: Thu, 7 Dec 2017 05:47:45 +0000

Dear All,

I am a Beginner for NONMEM. I am having a dataset of oral BE study. The Dru=
g is BCS III and tmax is 0.5-2hrs. I have observed lag time and double peak=
; but I am not assure it is double peak or sampling error. I have used ALAG=
 in the control file to deal with lag time. The half of the subjects are fo=
llowing 1 compartmental absorption and the rest are following 2 compartment=
al absorption. So I separately modeling each compartment. Is it right metho=
d?? Should I use transit model?

The elimination phase is captured well; but I am unable to achieve Maximum =
Concentration. The CWRES vs. Time & CWRES vs.PRED plots clearly indicates b=
ias at high concentration.

Please suggest me some needful actions to deal with these problems.


Best Regards
Anuja


"Disclaimer: Legally privileged confidential information, binding only if
confirmed in writing by a person authorized by Cipla. Please notify sender
immediately and permanently delete message if you are not intended recipien=
t.
This email is an informal communication and not a definitive opinion of the
company or the author. Thoughts or ideas expressed here may be incomplete or
in error and subject to further review and change. Thank you."







Received on Thu Dec 07 2017 - 00:47:45 EST