NONMEM Users Network Archive

Hosted by Cognigen

[NMusers] SCM error: Multiple instances of label in problem to update

From: Amir Youssef <amir.youssef.7_at_gmail.com>
Date: Fri, 1 May 2015 11:38:46 -0400

Dear all,

I am running the SCM tool in PsN but I am getting the following error:
"Multiple instances of label [P]_ in problem to update, ambiguous parameter
matching by label. at C:\Perl64\site\lib/PsN_4_2_0/model.pm line 3424."

This is a 2 compartment model with oral absorption (ADVAN 4) parameterized
in CL and Q (i.e.: TRANS 4) with lag time. Here is the scm config file:

model=125_COV.ctl
directory=scm-both-125
search_direction=both
only_successful=1
parallel_states=1
p_forward=0.05
p_backward=0.01
continuous_covariates=WTKG,HTCM,BMIKGM2,AGEYR,TBILIUM,ASTUL,ALTUL,GGTUL,ALPUL,CRUM,BUNMM,UACUM,UPGL,ECRCL
categorical_covariates=SEXF
do_not_drop=WTKG,HTCM,BMIKGM2,AGEYR,TBILIUM,ASTUL,ALTUL,GGTUL,ALPUL,CRUM,BUNMM,UACUM,UPGL,ECRCL,SEXF
missing_data_token=-99
linearize=0
nm_version=default
retries=2
threads=4

[test_relations]
CL=
SEXF,WTKG,HTCM,BMIKGM2,AGEYR,TBILIUM,ASTUL,ALTUL,GGTUL,ALPUL,CRUM,BUNMM,UACUM,UPGL,ECRCL
V2=
SEXF,WTKG,HTCM,BMIKGM2,AGEYR,TBILIUM,ASTUL,ALTUL,GGTUL,ALPUL,CRUM,BUNMM,UACUM,UPGL,ECRCL

[valid_states]
continuous = 1,5
catagorical=1,2


Many thanks in advance for your help.

Amir

Received on Fri May 01 2015 - 11:38:46 EDT