NONMEM Users Network Archive

Hosted by Cognigen

Re: [NMusers] $SIZES failed

From: luann <Luann.Phillips_at_cognigencorp.com>
Date: Wed, 17 Jun 2015 18:15:38 -0400

Hi Sam,

If you are running NM 7.3, run the control stream using the option
-tprdefault instead of -prdefault.
This will make sure that NONMEM recompiles the appropriate files.

Best regards,
Luann

On 6/17/2015 4:35 PM, Sam Liao wrote:
> Hi,
> My PK model has 42 theta and 35 omega exceeding the default limits.
> When I used $SIZE to change these size in my control file, I still get
> the error msg from nmtran.exe
> "MAY NOT USE -prdefault: LVR IN SIZES.f90 WOULD NEED TO BE INCREASED
> TO 35"
>
> Is there way to get around this problem? Somehow, the $SIZE statement
> in the control stream was ignored.
>

--
*Luann Phillips*| Director, Pharmacometrics
Cognigen Corporation, a wholly owned subsidiary of Simulations Plus, Inc.
1780 Wehrle Drive, Suite 110 | Buffalo, NY 14221-7000
Phone: 716.633.3463 x236 | Fax: 716.633.7404 |
luann.phillips_at_cognigencorp.com <mailto:luann.phillips_at_cognigencorp.com>

Received on Wed Jun 17 2015 - 18:15:38 EDT

The NONMEM Users Network is maintained by ICON plc. Requests to subscribe to the network should be sent to: nmusers-request_at_iconplc.com. Once subscribed, you may contribute to the discussion by emailing: nmusers@globomaxnm.com.